Background Background
Modification JM7813 installed a ground inhibit relay and ground test relay to prevent the operation of the stall warning system until the aircraft has been airborne for at least three seconds. Investigation by BAe has shown that a failure of the ground test relay in the energised position would cause a failure in the stall warning system with no indication to the crew of the malfunction.