1. Visually inspect the elevator trim cable guide tube for severance. Severance is defined as any cut, break, or division of the elevator trim cable guide tube (generally performed to gain access to the trim cable turnbuckles).
2. If severance is found , splice the elevator trim cable guide tube and install an external sleeve in accordance with the instructions in Elevator Trim Cable Guide Tube Splice Kit, Piper Part Number 766-272.
Note 1. Piper Kit 766-272 is referenced in Piper SB 953.
Note 2. Revised maintenance procedures on gaining access to the trim cable turnbuckles may be obtained from the manufacturer.
Note 3. FAA AD 92-13-06 Amdt 39-8276 refers.