Requirement
Requirement Requirement
Inspection as prescribed in Bombardier Rotax Technical Bulletin 912-18 to be carried out. There are three steps to the Rotax directive, viz:
Step 1. Inspection of engine oil filter and magnetic drain plug before next flight.
Abnormal results of this inspection will require an engine removal and return to Rotax for repair. If inspection satisfactory, proceed to Step 2.
Step 2. Within 100 operating hours after Step 1, measure camshaft hardness. If satisfactory, engine is clear of further action and normal operations may resume. If not satisfactory, repeat Step 1 every 100 operating hours until 600 operating hours reached and then take Step 3.
Step 3. Return engine to Rotax agent for replacement of the defective camshaft.
The statute text is free to read above. View subscription options to unlock the case-law research tools for each provision.