Mechanical ventilation system - required redundancy
2.5 Mechanical ventilation system - required redundancy
If a mechanical ventilation system is fitted, the vessel must carry, for each type of fan in the system, either:
spare fans; or
spare parts, including:
a complete electrical motor;
a complete rotor or impeller;
any other parts required for repair.
If a mechanical ventilation system is fitted on a vessel, fan starters must be divided into at least 2 group starter panels.
Each group starter panel must be:
located in a space that is not adjacent to a space where another group starter panel is located; and
supplied with power from both the main and secondary sources of power; and
interlocked to prevent simultaneous supply of power from both main and secondary sources.
The main and secondary sources of power supplying ventilation services must be as widely separated as practicable, with power from neither passing through a space that contains any part of the other source of power.
Fans controlled by each group starter panel must be able to ventilate all livestock spaces on the vessel in accordance with clauses 2.1 to 2.3.