2.8. Block crush strength specification
Eight samples are to be tested from four locations, evenly spaced across the block. For a block to pass certification, seven of the eight samples shall meet the crush strength specification of the previous section.
3. ADHESIVE BONDING PROCEDURE
3.1. Immediately before bonding, aluminium sheet surfaces to be bonded shall be thoroughly cleaned using a suitable solvent, such as 1-1-1 Trichloroethane.
This is to be carried out at least twice or as required to eliminate grease or dirt deposits. The cleaned surfaces shall then be abraded using 120 grit abrasive paper.
Metallic/Silicon Carbide abrasive paper is not to be used. The surfaces shall be thoroughly abraded and the abrasive paper changed regularly during the process to avoid clogging, which may lead to a polishing effect. Following abrading, the surfaces shall be thoroughly cleaned again, as above. In total, the surfaces shall be solvent cleaned at least four times. All dust and deposits left as a result of the abrading process shall be removed, as these will adversely affect bonding.
3.2. The adhesive should be applied to one surface only, using a ribbed rubber roller. In cases where honeycomb is to be bonded to aluminium sheet, the adhesive should be applied to the aluminium sheet only. A maximum of 0.5 kg/m2 shall be applied evenly over the surface, giving a maximum film thickness of 0.5 mm.
4.1. The main honeycomb block shall be bonded to the backing sheet with adhesive such that the cell axes are perpendicular to the sheet.
The cladding shall be bonded to the front surface of the honeycomb block. The top and bottom surfaces of the cladding sheet shall not be bonded to the main honeycomb block but should be positioned closely to it. The cladding sheet shall be adhesively bonded to the backing sheet at the mounting flanges.
4.2. The bumper element shall be adhesively bonded to the front of the cladding sheet such that the cell axes are perpendicular to the sheet.
The bottom of the bumper element shall be flush with the bottom surface of the cladding sheet. The bumper facing sheet shall be adhesively bonded to the front of the bumper element.
4.3. The bumper element shall then be divided into three equal sections by means of two horizontal slots.
These slots shall be cut through the entire depth of the bumper section and extend the whole width of the bumper. The slots shall be cut using a saw; their width shall be the width of the blade used and shall not exceed 4.0 mm.
4.4. Clearance holes for mounting the barrier are to be drilled in the mounting flanges (shown in Figure 5).
The holes shall be of 9.5 mm diameter. Five holes shall be drilled in the top flange at a distance of 40 mm from the top edge of the flange and five in the bottom flange, 40 mm from the bottom edge of that flange. The holes shall be at 100 mm, 300 mm, 500 mm, 700 mm, 900 mm from either edge of the barrier distances. All holes shall be drilled to ( 1 mm of the nominal
5.1. The deformable barrier shall be rigidly fixed to the edge of a mass of not less than 7 x 104 kg or to some structure attached thereto.
The attachment of the barrier face shall be such that the vehicles shall not contact any part of the structure more than 75 mm from the top surface of the barrier (excluding the upper flange) during any stage of the impact2/. The front face of the surface to which the deformable barrier is attached shall be flat and continuous over the height and width of the face and shall be vertical ( 1° and perpendicular ( 1° to the axis of the run-up track. The attachment surface shall not be displaced by more than 10 mm during the test. If necessary, additional anchorage or arresting devices shall be used to prevent displacement of the concrete block. The edge of the deformable barrier shall be aligned with the edge of the concrete block appropriate for the side of the vehicle to be tested.
5.2. The deformable barrier shall be fixed to the concrete block by means of ten bolts, five in the top mounting flange and five in the bottom.
These bolts shall be of at least 8 mm diameter. Steel clamping strips shall be used for both the top and bottom mounting flanges (see Figures 1 and 5). These strips shall be 60 mm high and 1000 mm wide and have a thickness of at least 3 mm. Five clearance holes of 9.5 mm diameter shall be drilled in both strips to correspond with those in the mounting flange on the barrier (see paragraph 4). None of the fixtures shall fail in the impact test.
Deformable barrier for frontal impact testing
Locations of samples for certification
Honeycomb axes and measured dimensions
Crush force and displacement
Positions of holes for barrier mounting
CERTIFICATION PROCEDURE FOR THE DUMMY LOWER LEG AND FOOT
1.1. The objective of this test is to measure the response of Hybrid III tibia skin and insert to well-defined, hard-faced pendulum impacts.
1.2. Left and right Hybrid III leg assemblies, from the knee clevis joint down, shall be used. Each shall be attached rigidly to the test fixture.
1.3.1. Each leg assembly shall be maintained (soaked) for 4 hours prior to the test at a temperature of 22 ( 3°C and a relative humidity of 40 30 per cent. The soak period shall not include the time required to reach steady state conditions.
1.3.2. Align the impactor accelerometer with its sensitive axis parallel to the impactor longitudinal centre line.
1.3.3. Clean the impact surface of the skin and also the impactor face with isopropyl alcohol or equivalent prior to the test.
1.3.4. Mount the leg assembly to the fixture at the knee clevis joint, as shown in Figure 1. The test fixture shall be rigidly secured to prevent movement during impact. The test fixture shall be constructed such that there is no contact with any part of the leg assembly, other than at the fixing point, during the test. The line between the knee clevis joint and the centre of the ankle joint shall be vertical ( 5°. Adjust the knee and ankle joint to 1,5 ( 0,5 g range before each test.
1.3.5. The rigid impactor shall have a mass of 5,0 ( 0,2 kg including instrumentation. The impact face shall be a half cylinder with its principal axis horizontal ( 1° and perpendicular to the direction of impact. The radius of the impact surface shall be 40 ( 2 mm and the width of the impact surface shall be at least 80 mm. The impactor shall strike the tibia at a point midway between the knee clevis joint and the ankle pivot along the centre line of the tibia. The impactor shall strike the tibia so that the horizontal centre line of the impactor falls within 0,5° of a horizontal line parallel to the femur load cell simulator at time-zero. The impactor shall be guided to exclude significant lateral, vertical or rotational movement at time-zero .
1.3.6. Allow a period of at least 30 minutes between successive tests on the same leg.
1.3.7. The data acquisition system, including transducers, shall conform to the specifications for CFC 600, as described in annex 8.
1.4. Performance specification
1.4.1. When each tibia is impacted at 2.1 ( 0,3 m/s in accordance with paragraph 1.3., the impact force, which is the product of the pendulum mass and the deceleration, shall be 2.3 ( 0,3 kN.
2. UPPER FOOT IMPACT TEST
2.1. The objective of this test is to measure the response of the Hybrid III foot and ankle to well-defined, hard-faced pendulum impacts.
2.2. The complete Hybrid III lower leg assembly, left (86-5001-001) and right (86-5001-002), equipped with the foot and ankle assembly, left (78051-614) and right (78051-615), shall be used, including the knee assembly. The load cell simulator (78051-319 Rev A) shall be used to secure the knee-cap assembly (78051-16 Rev B) to the test fixture.
2.3.1. Each leg assembly shall be maintained (soaked) for 4 hours prior to the test at a temperature of 22 ( 3°C and a relative humidity of 40 ( 30 per cent. The soak period shall not include the time required to reach steady state conditions.
2.3.2. a) Clean the impact surface of the skin and also the impactor face with isopropyl alcohol or equivalent prior to the test.
b) Align the impactor accelerometer with its sensitive axis parallel to the direction of impact at contact with the foot.
2.3.3. Mount the leg assembly to the fixture shown in Figure 1a. The test fixture shall be secured rigidly to prevent movement during the impact test. The centre line of the femur load cell simulator (78051-319) shall be vertical ( 0,5°. Adjust the mount such that the line joining the knee clevis joint and the ankle attachment bolt is horizontal ( 3° with the heel resting on two sheets of low-friction (PTFE) material. Ensure that the tibia flesh is located towards the knee end of the tibia. Adjust the ankle such that the plane of the underside of the foot is vertical ( 3°. Adjust the knee and ankle joint to 1,5 ( 0,5 g range before each test.
2 3.4. The rigid impactor comprises a horizontal cylinder diameter 50 ( 2 mm and a pendulum support arm diameter 19 ( 1 mm (Figure 3a). The cylinder has a mass of 1,25 ( 0,02 kg including instrumentation and any part of the support arm within the cylinder. The pendulum arm has a mass of 285 ( 5 g. The mass of any rotating part of the axle to which the support arm is attached should not be greater than100 g. The length between the central horizontal axis of the impactor cylinder and the axis of rotation of the whole pendulum shall be 1250 ( 1 mm. The impact cylinder is mounted with its longitudinal axis horizontal and perpendicular to the direction of impact. The pendulum shall impact the underside of the foot, at a distance of 185 ( 2 mm from the base of the heel resting on the rigid horizontal platform, so that the longitudinal centre line of the pendulum arm falls within 1° of a vertical line at impact. The impactor shall be guided to exclude significant lateral, vertical or rotational movement at time-zero.
2.3.5. Allow a period of at least 30 minutes between successive tests on the same leg.
2.3.6. The data acquisition system, including transducers, shall conform to the specifications for CFC 600, as described in annex 8.
2.4. Performance specifications
2.4.1. When the ball of each foot is impacted at 6,7 ( 0,2 m/s in accordance with paragraph 2.3., the maximum tibia bending moment about they-axis (My) shall be between 100 Nm and 140 Nm.
3. LOWER FOOT IMPACT TEST
3.1. The objective of this test is to measure the response of the Hybrid III foot skin and insert to well-defined, hard-faced pendulum impacts.
3.2. The complete Hybrid III lower leg assembly, left (86-5001-001) and right (86-5001-002), equipped with the foot and ankle assembly, left (78051-614) and right (78051-615), shall be used, including the knee assembly. The load cell simulator (78051-319 Rev A) shall be used to secure the knee-cap assembly (78051-16 Rev B) to the test fixture.
3.3.1. Each leg assembly shall be maintained (soaked) for 4 hours prior to the test at a temperature of 22 ( 3°C and a relative humidity of 40 ( 30 per cent. The soak period shall not include the time required to reach steady state conditions.
3.3.2. Align the impactor accelerometer with its sensitive axis parallel to the impactor longitudinal centre line.
3.3.3. Clean the impact surface of the skin and also the impactor face with isopropyl alcohol or equivalent prior to the test.
3.3.4. Mount the leg assembly to the fixture shown in Figure 1b. The test fixture shall be secured rigidly to prevent movement during the impact test. The centre line of the femur load cell simulator (78051-319) shall be vertical ( 0,5°. Adjust the mount such that the line joining the knee clevis joint and the ankle attachment bolt is horizontal ( 3° with the heel resting on two sheets of low-friction (PTFE) material. Ensure that the tibia flesh is located towards the knee end of the tibia. Adjust the ankle such that the plane of the underside of the foot is vertical ( 3°. Adjust the knee and ankle joint to 1,5 ( 0,5 g range before each test.
3.3.5. The rigid impactor comprises a horizontal cylinder diameter 50 ( 2 mm and a pendulum support arm diameter 19 ( 1 mm (Figure 3a). The cylinder has a mass of 1,25 ( 0,02 kg including instrumentation and any part of the support arm within the cylinder. The pendulum arm has a mass of 285 ( 5 g. The mass of any rotating part of the axle to which the support arm is attached should not be greater than 100 g. The length between the central horizontal axis of the impactor cylinder and the axis of rotation of the whole pendulum shall be 1250 ( 1 mm. The impact cylinder is mounted with its longitudinal axis horizontal and perpendicular to the direction of impact. The pendulum shall impact the underside of the foot, at a distance of 62 ( 2 mm from the base of the heel resting on the rigid horizontal platform, so that the longitudinal centre line of the pendulum arm falls within 1° of a vertical line at impact. The impactor shall be guided to exclude significant lateral, vertical or rotational movement at time-zero.
3.3.6. Allow a period of at least 30 minutes between successive tests on the same leg.
3.3.7. The data acquisition system, including transducers, shall conform to the specifications for CFC 600, as described in annex 8.
3.4. Performance specification
3.4.1. When the heel of each foot is impacted at 4,4 ( 0,2 m/s in accordance with paragraph 3.3., the maximum impactor acceleration shall be 340 ( 50 g.
Tibia impact test - test set-up specifications
Upper foot impact test - test set-up specifications
Lower foot impact test - test set-up specifications
Upper foot impact test - test set-up specifications
Lower foot impact test - test set-up specifications