Ventilation system
430 Ventilation system
The operator of a prescribed mine must ensure that—
ventilation circuits at the mine do not allow airflows to recirculate; and
structures that regulate airflow are maintained in operating condition; and
air does not pass through so many work areas that it becomes unfit to breathe; and
dead-end openings are not worked unless adequate auxiliary ventilation is provided; and
underground workings are not ventilated with contaminated air.
Note
Act compliance—sections 21, 23 and 26 (see regulation 7).
The operator of a prescribed mine must regularly monitor and test the operation of all aspects of the ventilation system at the mine to ensure that the system complies with subregulation (1).
Note
Act compliance—section 22(1) (see regulation 7).