Attachment 1.10
Attachment 1.10 Attachment 1.10
Category : Commercial
General Area Served : Brisbane (QLD)
Service Licence Number : SL4161
TECHNICAL SPECIFICATION - AM Radio
Specification Number : TS10013948
Transmitter Site :-
Nominal location : Broadcast site 273 Queens Rd NUDGEE
Nominal Co-ordinates Latitude Longitude
: -27.358757 153.089738
Site Tolerance : Refer to Broadcasting Services (Technical Planning) Guidelines 2017
Emission :-
Frequency Band & Mode: MF-AM
Carrier Frequency : 1116 kHz
Night-time Output Radiation Pattern :-
Bearing or Sector (Clockwise direction)
Elevation
Maximum CMF
0°T
0
890 V
10°T
0
1.03 kV
20°T
0
1.1 kV
30°T
0
1.1 kV
40°T
0
1.055 kV
50°T
0
975 V
60°T
0
890 V
70°T
0
820 V
80°T
0
780 V
90°T
0
770 V
100°T
0
795 V
110°T
0
855 V
120°T
0
930 V
130°T
0
1.015 kV
140°T
0
1.08 kV
150°T
0
1.11 kV
160°T
0
1.075 kV
170°T
0
965 V
180°T
0
795 V
190°T
0
580 V
200°T
0
365 V
210°T
0
260 V
220°T
0
355 V
230°T
0
500 V
240°T
0
625 V
250°T
0
710 V
260°T
0
755 V
270°T
0
765 V
280°T
0
740 V
290°T
0
675 V
300°T
0
570 V
310°T
0
430 V
320°T
0
290 V
330°T
0
290 V
340°T
0
465 V
350°T
0
690 V
Special Conditions:
The specified radiation pattern is for night-time operation. The licensee must comply with the specification from one hour before local sunset to one hour after local sunrise, as defined at the transmitter site on the 15th day of each month.
The CMF at all elevations is not to exceed the specified CMF at 0 degrees elevation for all angles of azimuth.
Daytime Output Radiation Pattern :-
Bearing or Sector (Clockwise direction)
Elevation
Maximum CMF
0°T
0
1.675 kV
10°T
0
1.395 kV
20°T
0
1.05 kV
30°T
0
710 V
40°T
0
500 V
50°T
0
520 V
60°T
0
670 V
70°T
0
810 V
80°T
0
890 V
90°T
0
910 V
100°T
0
860 V
110°T
0
745 V
120°T
0
590 V
130°T
0
480 V
140°T
0
575 V
150°T
0
870 V
160°T
0
1.225 kV
170°T
0
1.545 kV
180°T
0
1.775 kV
190°T
0
1.885 kV
200°T
0
1.87 kV
210°T
0
1.75 kV
220°T
0
1.56 kV
230°T
0
1.35 kV
240°T
0
1.16 kV
250°T
0
1.015 kV
260°T
0
930 V
270°T
0
910 V
280°T
0
965 V
290°T
0
1.08 kV
300°T
0
1.25 kV
310°T
0
1.455 kV
320°T
0
1.66 kV
330°T
0
1.82 kV
340°T
0
1.895 kV
350°T
0
1.85 kV
Special Conditions:
The specified radiation pattern is for daytime operation. The licensee must comply with the specification from one hour after local sunrise to one hour before local sunset, as defined at the transmitter site on the 15th day of each month.
The CMF at all elevations is not to exceed the specified CMF at 0 degrees elevation for all angles of azimuth.
The statute text is free to read above. View Pro plans to unlock the case-law research tools for each provision.