Attachment 1.8
Attachment 1.8 Attachment 1.8
Category : Commercial
General Area Served : Brisbane (QLD)
Service Licence Number : SL4165
TECHNICAL SPECIFICATION - AM Radio
Specification Number : TS10014414
Transmitter Site :-
Nominal location : Broadcast Site 1871 Wynnum Rd WYNNUM WEST
Nominal Co-ordinates Latitude Longitude
: -27.463526 153.146483
Site Tolerance : Refer to Broadcasting Services (Technical Planning) Guidelines 2017
Emission :-
Frequency Band & Mode MF-AM
Carrier Frequency : 693 kHz
Night-time Output Radiation Pattern :-
Bearing or Sector (Clockwise direction)
Elevation
Maximum CMF
0°T
0
825 V
10°T
0
680 V
20°T
0
500 V
30°T
0
320 V
40°T
0
165 V
50°T
0
150 V
60°T
0
245 V
70°T
0
330 V
80°T
0
380 V
90°T
0
390 V
100°T
0
360 V
110°T
0
290 V
120°T
0
195 V
130°T
0
145 V
140°T
0
260 V
150°T
0
440 V
160°T
0
630 V
170°T
0
795 V
180°T
0
915 V
190°T
0
980 V
200°T
0
990 V
210°T
0
945 V
220°T
0
865 V
230°T
0
765 V
240°T
0
665 V
250°T
0
585 V
260°T
0
535 V
270°T
0
525 V
280°T
0
555 V
290°T
0
620 V
300°T
0
705 V
310°T
0
805 V
320°T
0
895 V
330°T
0
955 V
340°T
0
970 V
350°T
0
925 V
Special Conditions:
The specified radiation pattern is for night-time operation. The licensee must comply with the specification from one hour before local sunset to one hour after local sunrise, as defined at the transmitter site on the 15th day of each month.
The CMF at all elevations is not to exceed the specified CMF at 0 degrees elevation for all angles of azimuth.
Daytime Output Radiation Pattern :-
Bearing or Sector (Clockwise direction)
Elevation
Maximum CMF
0°T
0
1.17 kV
10°T
0
960 V
20°T
0
710 V
30°T
0
450 V
40°T
0
235 V
50°T
0
210 V
60°T
0
345 V
70°T
0
465 V
80°T
0
540 V
90°T
0
555 V
100°T
0
510 V
110°T
0
410 V
120°T
0
275 V
130°T
0
205 V
140°T
0
365 V
150°T
0
625 V
160°T
0
890 V
170°T
0
1.12 kV
180°T
0
1.29 kV
190°T
0
1.385 kV
200°T
0
1.395 kV
210°T
0
1.335 kV
220°T
0
1.22 kV
230°T
0
1.08 kV
240°T
0
940 V
250°T
0
825 V
260°T
0
760 V
270°T
0
745 V
280°T
0
785 V
290°T
0
875 V
300°T
0
1 kV
310°T
0
1.135 kV
320°T
0
1.26 kV
330°T
0
1.345 kV
340°T
0
1.37 kV
350°T
0
1.31 kV
Special Conditions: