Barrister AI
All legislation
COMMONWEALTHLegislative Instrument
In force
This is the latest official compilation.Check the official source →
Attachment 1.8

Attachment 1.8

In force
Schedule SixSchedule Six

Attachment 1.8 Attachment 1.8

Category : Commercial

General Area Served : Brisbane (QLD)

Service Licence Number : SL4165

TECHNICAL SPECIFICATION - AM Radio

Specification Number : TS10014414

Transmitter Site :-

Nominal location : Broadcast Site 1871 Wynnum Rd WYNNUM WEST

Nominal Co-ordinates Latitude Longitude

(GDA94)

: -27.463526 153.146483

Site Tolerance : Refer to Broadcasting Services (Technical Planning) Guidelines 2017

Emission :-

Frequency Band & Mode MF-AM

Carrier Frequency : 693 kHz

Night-time Output Radiation Pattern :-

Bearing or Sector (Clockwise direction)

Elevation

Maximum CMF

0°T

0

825 V

10°T

0

680 V

20°T

0

500 V

30°T

0

320 V

40°T

0

165 V

50°T

0

150 V

60°T

0

245 V

70°T

0

330 V

80°T

0

380 V

90°T

0

390 V

100°T

0

360 V

110°T

0

290 V

120°T

0

195 V

130°T

0

145 V

140°T

0

260 V

150°T

0

440 V

160°T

0

630 V

170°T

0

795 V

180°T

0

915 V

190°T

0

980 V

200°T

0

990 V

210°T

0

945 V

220°T

0

865 V

230°T

0

765 V

240°T

0

665 V

250°T

0

585 V

260°T

0

535 V

270°T

0

525 V

280°T

0

555 V

290°T

0

620 V

300°T

0

705 V

310°T

0

805 V

320°T

0

895 V

330°T

0

955 V

340°T

0

970 V

350°T

0

925 V

Special Conditions:

The specified radiation pattern is for night-time operation. The licensee must comply with the specification from one hour before local sunset to one hour after local sunrise, as defined at the transmitter site on the 15th day of each month.

The CMF at all elevations is not to exceed the specified CMF at 0 degrees elevation for all angles of azimuth.

Daytime Output Radiation Pattern :-

Bearing or Sector (Clockwise direction)

Elevation

Maximum CMF

0°T

0

1.17 kV

10°T

0

960 V

20°T

0

710 V

30°T

0

450 V

40°T

0

235 V

50°T

0

210 V

60°T

0

345 V

70°T

0

465 V

80°T

0

540 V

90°T

0

555 V

100°T

0

510 V

110°T

0

410 V

120°T

0

275 V

130°T

0

205 V

140°T

0

365 V

150°T

0

625 V

160°T

0

890 V

170°T

0

1.12 kV

180°T

0

1.29 kV

190°T

0

1.385 kV

200°T

0

1.395 kV

210°T

0

1.335 kV

220°T

0

1.22 kV

230°T

0

1.08 kV

240°T

0

940 V

250°T

0

825 V

260°T

0

760 V

270°T

0

745 V

280°T

0

785 V

290°T

0

875 V

300°T

0

1 kV

310°T

0

1.135 kV

320°T

0

1.26 kV

330°T

0

1.345 kV

340°T

0

1.37 kV

350°T

0

1.31 kV

Special Conditions:

The specified radiation pattern is for daytime operation. The licensee must comply with the specification from one hour after local sunrise to one hour before local sunset, as defined at the transmitter site on the 15th day of each month.

The CMF at all elevations is not to exceed the specified CMF at 0 degrees elevation for all angles of azimuth.

Research tools for this sectionPro

The statute text is free to read above. View Pro plans to unlock the case-law research tools for each provision.

Section Attachment 1.8 — Attachment 1.8 — Licence Area Plan - Brisbane Radio (Commonwealth) — Barrister AI