59
In forceOther requirements for accuracy of meter—100TJ to 1PJ
Part 6Metering parameters
59 Other requirements for accuracy of meter—100TJ to 1PJ
(1)
This section applies in relation to a meter that measures 100TJ or more, but not more than 1PJ, a year.
(2)
The controller of the meter must ensure the meter is installed with a device to correct the meter’s readings to standard temperature and pressure.
(3)
The overall tolerance for error for the meter, including the correcting device, is plus or minus 1%.
(4)
The accuracy of the meter must be checked at least once in each 6-month period.