Schedule 11
CurrentPlacard and Manifest Quantities
Schedule 11 Placard and Manifest Quantities
Regulations 347 – 350, 361, 390 and 391
| Column 1 | Column 2 | Column 3 | Column 4 | Column 5 |
|---|---|---|---|---|
| Item | Description | of hazardous chemical | Placard quantity | Manifest quantity |
| Flammable gases | Category 1A, category 1B or any combination of categories 1A and 1B | 200L | 5 000L | |
| Gases under pressure | With acute toxicity, category 1, 2, 3 or 4 | 50L | 500L | |
| With skin corrosion, category 1A, 1B or 1C | 50L | 500L | ||
| Not specified elsewhere in this table | 1 000L | 10 000L | ||
| Flammable liquids | Category 1 | 50L | 500L | |
| Category 2 | 250L | 2 500L | ||
| Category 3 | 1 000L | 10 000L | ||
| Any combination of chemicals from items 5 to 7 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000L | 10 000L | ||
| Category 4 | 10 000L | 100 000L | ||
| Self-reactive substances | Type A | 5kg or 5L | 50kg or 50L | |
| Type B | 50kg or 50L | 500kg or 500L | ||
| Type C to F | 250kg or 250L | 2 500kg or 2 500L | ||
| Flammable solids | Category 1 | 250kg | 2 500kg | |
| Category 2 | 1 000kg | 10 000kg | ||
| Any combination of chemicals from items 11 to 14 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Pyrophoric liquids and pyrophoric solids | Category 1 | 50kg or 50L | 500kg or 500L | |
| Self-heating substances and mixtures | Category 1 | 250kg or 250L | 2 500kg or 2 500L | |
| Category 2 | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Any combination of chemicals from items 16 to 18 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Substances which in contact with water emit flammable gas | Category 1 | 50kg or 50L | 500kg or 500L | |
| Category 2 | 250kg or 250L | 2 500kg or 2 500L | ||
| Category 3 | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Any combination of chemicals from items 20 to 22 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Oxidising liquids and oxidising solids | Category 1 | 50kg or 50L | 500kg or 500L | |
| Category 2 | 250kg or 250L | 2 500kg or 2 500L | ||
| Category 3 | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Any combination of chemicals from items 24 to 26 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Organic peroxides | Type A | 5kg or 5L | 50kg or 50L | |
| Type B | 50kg or 50L | 500kg or 500L | ||
| Type C to F | 250kg or 250L | 2 500kg or 2 500L | ||
| Any combination of chemicals from items 29 and 30 where none of the items exceeds the quantities in columns 4 or 5 on their own | 250kg or 250L | 2 500kg or 2 500L | ||
| Acute toxicity | Category 1 | 50kg or 50L | 500kg or 500L | |
| Category 2 | 250kg or 250L | 2 500kg or 2 500L | ||
| Category 3 | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Any combination of chemicals from items 32 to 34 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Skin corrosion | Category 1A | 50kg or 50L | 500kg or 500L | |
| Category 1B | 250kg or 250L | 2 500kg or 2 500L | ||
| Category 1C | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Corrosive to metals | Category 1 | 1 000kg or 1 000L | 10 000kg or 10 000L | |
| Any combination of chemicals from items 36 to 39 where none of the items exceeds the quantities in columns 4 or 5 on their own | 1 000kg or 1 000L | 10 000kg or 10 000L | ||
| Unstable explosives | 5kg or 5L | 50kg or 50L | ||
| Unstable chemicals | Any combination of chemicals from items 10, 28 and 41 where none of the items exceeds the quantities in columns 4 or 5 on their own | 5kg or 5L | 50kg or 50L | |
| Aerosols | Category 1, category 2, category 3 or any combination of categories 1, 2 and 3 | 5 000L | 10 000L |
| Notes | |
| In item 2, Gases under pressure with acute toxicity, category 4 only applies up to a LC50 of 5 000 ppmV. This is equivalent to dangerous goods of Division 2.3. | |
| Item 43 includes flammable aerosols. |
| 1 | Determination of classification of flammable liquids |
| For the purposes of this table, if a flammable liquid category 4 is used, handled or stored in the same spill compound as one or more flammable liquids of categories 1, 2 or 3, the total quantity of flammable liquids categories 1, 2 or 3 must be determined as if the flammable liquid category 4 had the same classification as the flammable liquid in the spill compound with the lowest flash point. |
| Example |
| For placarding and manifest purposes, a spill compound containing 1 000L of flammable liquid category 1 and 1 000L of flammable liquid category 4 is considered to contain 2 000L of flammable liquid category 1. |
Research tools for this sectionSubscription
The statute text is free to read above. View subscription options to unlock the case-law research tools for each provision.