Level indicator system or relief valve for cement storage silo

In force

8 Level indicator system or relief valve for cement storage silo

(1)

A level indicator system for a cement storage silo must include —

(a)

an audible alarm which sounds if cement stored in the silo reaches —

(i)

0.6 m below the inlet to the silo’s air cleaning system; or

(ii)

2 tonnes less than the silo’s maximum capacity;

and

(b)

a test circuit which indicates whether the level indicator and alarm are working correctly.

(2)

Where a level indicator is used to comply with regulation 6(2)(b) the operator must ensure that the test circuit is activated before a load of cement is unloaded into the silo and that no cement is unloaded into the silo if the level indicator or alarm are not working correctly.

(3)

A relief valve for a cement storage silo must be designed —

(a)

to automatically prevent the level of cement in the silo rising above the level referred to in subregulation (1)(a)(i) or (ii); and

(b)

so that any excess cement is piped into a weigh hopper or to an outlet which is within one metre of the ground.