Barrister AI
All legislation
COMMONWEALTHRegulation
In force
This is the latest official compilation.Check the official source →
Schedule 5

Maximum permissible uncertainty—mass (State primary, secondary and tertiary standards)

In force

Schedule 5 Maximum permissible uncertainty—mass (State primary, secondary and tertiary standards)

(paragraphs 18(5)(b) and (c), 25(b) and 26(a) and subparagraphs 25(d)(i) and 26(c)(i))

Column 1

Denomination

Column 2

Maximum permissible uncertainty (at 95% level of confidence): State primary standard (in mg)

Column 3

Maximum permissible uncertainty (at 95% level of confidence): State secondary standard (in mg)

Column 4

Maximum permissible uncertainty (at 95% level of confidence): State tertiary standard (in mg)

50 kg

84.000

267.00

25 kg

42.000

127.00

20 kg

10.000

33.000

100.00

10 kg

5.000

17.000

53.00

5 kg

3.000

8.000

27.00

2 kg

1.000

3.000

10.00

1 kg

0.500

2.000

6.00

500 g

0.300

0.800

2.70

200 g

0.100

0.300

1.00

100 g

0.050

0.200

0.60

50 g

0.030

0.100

0.40

20 g

0.030

0.080

0.30

10 g

0.020

0.070

0.20

5 g

0.020

0.050

0.17

2 g

0.010

0.040

0.14

1 g

0.010

0.030

0.10

500 mg

0.008

0.030

0.09

200 mg

0.007

0.020

0.07

100 mg

0.005

0.020

0.06

50 mg

0.004

0.010

0.04

20 mg

0.003

0.010

0.04

10 mg

0.003

0.008

0.03

5 mg

0.002

0.007

0.02

2 mg

0.002

0.007

0.02

1 mg

0.002

0.007

0.02

Note: The maximum permissible uncertainties in this table are based on OIML R 111.