reg 10.1

If the system has a holding tank that requires pump out and flushing—

In force

10.1 If the system has a holding tank that requires pump out and flushing—

(a)

provision must be made for flushing the tank with fresh water at times when it is being pumped out; and

(b)

the flush and pump out fittings must have a gastight cover for when they are not in use; and

(c)

the houseboat must be fitted with a 32 millimetre (1∙25 inch) internal diameter standard camlock adaptor compatible with pump out fittings to discharge via the GMR Water Corporation's sanitation service stations.