reg 10.1
In forceIf the system has a holding tank that requires pump out and flushing—
10.1 If the system has a holding tank that requires pump out and flushing—
(a)
provision must be made for flushing the tank with fresh water at times when it is being pumped out; and
(b)
the flush and pump out fittings must have a gastight cover for when they are not in use; and
(c)
the houseboat must be fitted with a 32 millimetre (1∙25 inch) internal diameter standard camlock adaptor compatible with pump out fittings to discharge via the GMR Water Corporation's sanitation service stations.
Research tools for this sectionPro
The statute text is free to read above. View Pro plans to unlock the case-law research tools for each provision.