The system must be capable of operating so that for any treated greywater discharged from the system—

In force

17.2 The system must be capable of operating so that for any treated greywater discharged from the system—

(a)

the chemical oxygen demand is less than 15 mg/L; and

(b)

the concentration of suspended solids is less than 10 mg/L; and

(c)

the total oil and grease content is less than 10 mg/L; and

(d)

the turbidity is less than 5 nephelometric turbidity units; and

(e)

the total phosphorus content is less than 1 mg/L; and

(f)

the total nitrogen content is less than 10 mg/L; and

(g)

the concentration of E. coli is less than 10 cells per 100 mL.