reg 7.2

If an outlet of the suction pipe type is used, the lower end of the suction pipe must—

In force

7.2 If an outlet of the suction pipe type is used, the lower end of the suction pipe must—

(a)

terminate not more than 38 millimetres above the bottom of the sump of the holding tank; and

(b)

be installed to ensure that the suction pipe is connected to the houseboat at an angle no greater than 30°.

7.3 The wall fitting of the outlet must consist of a 32 millimetre (1∙25 inch) internal diameter standard camlock adaptor compatible with pump out fittings used on the GMR Water Corporation's sanitation service stations.